The Brink Renovent Sky 300 is a ventilation unit with heat recovery with a maximum ventilation capacity of 300 m3/h and low-energy fans.
Features of the Brink Renovent Sky 300:
• Steplessly adjustable airflow rates through a control unit (supplied with the appliance).
• Filter indication on the control unit/multiple switches.
• A completely new intelligent frost protection system that ensures that also at low outdoor temperatures the appliance’s performance remains optimal and that, if necessary, it activates the standard preheater.
• Low sound level
• Comes as standard with automatic bypass valve
• Constant flow control
• Low energy consumption
• High efficiency
The Brink Renovent Sky 300 is available in two types:
• “Renovent Sky 300”
• “Renovent Sky 300 Plus”
Compared to the Renovent Sky 300, the Renovent Sky 300 Plus has a more extensive control board which increases the connection options.
Excellent 300 | ||||||||||||||
Supply Voltage | 230V/50Hz | |||||||||||||
Dimensions (wxhxd) (mm) | 675 x 765 x 564 | |||||||||||||
Duct diameter (mm) | 160 | |||||||||||||
External diameter condensate discharge (mm) | 32 | |||||||||||||
Weight (kg) | 38 | |||||||||||||
Filter class | G3 (F7 optional for supply) | |||||||||||||
Fan Setting (factory setting) | 0 | 1 | 2 | 3 | max | |||||||||
Factory Setting (m3/hr) | 50 | 100 | 150 | 225 | 300 | |||||||||
Permissible resistance of duct system (Pa) | 3-76 | 11-28 | 26-66 | 56-142 | ||||||||||
Rated power (excl. preheater) (W) | 9.0-9.2 | 13.7-15.2 | 22.0-29.2 | 46.8-66.2 | ||||||||||
Rated current (excl. preheater) (A) | 0.104-0.107 | 0.150-0.161 | 0.214-0.274 | 0.403-0.578 | ||||||||||
Max. rated current (incl. preheater switched on) (A) | 6 | |||||||||||||
Cos | 0.368-0.374 | 0.391-0.416 | 0.447-0.463 | 0.505 | ||||||||||
Sound power | ||||||||||||||
(m3/h) | p (Pa) | Filter | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 | Total Lw (dB) | Total weighed (dB(A)) | ||
90
|
50 | ISO Coarse 60% | 60.3 | 56.5 | 52.3 | 47.7 | 37.8 | 29.2 | 18.2 | 20.9 | 62.4 | 48.6 | ||
100 | ISO Coarse 60% | 59.4 | 62.1 | 54.4 | 50.5 | 41.6 | 34.7 | 22.5 | 21.4 | 64.6 | 51.8 | |||
150
|
50 | ISO Coarse 60% | 60.9 | 65.2 | 59.6 | 55.4 | 45.7 | 40.0 | 27.7 | 21.7 | 67.7 | 56.3 | ||
100 | ISO Coarse 60% | 61.4 | 61.1 | 62.1 | 59.7 | 48.1 | 42.7 | 31.2 | 23.3 | 67.2 | 59.0 | |||
210
|
50 | ISO Coarse 60% | 63.6 | 63.9 | 65.9 | 64.2 | 53.1 | 48.2 | 38.2 | 28.0 | 70.6 | 63.3 | ||
100 | ISO Coarse 60% | 63.7 | 63.9 | 66.9 | 63.1 | 53.8 | 49.0 | 39.2 | 29.5 | 70.8 | 63.1 | |||
300
|
50 | ISO Coarse 60% | 70.0 | 70.0 | 73.5 | 70.2 | 60.7 | 56.6 | 48.7 | 41.2 | 77.4 | 70.0 | ||
100 | ISO Coarse 60% | 69.1 | 68.8 | 71.2 | 70.0 | 60.8 | 56.7 | 48.8 | 42.0 | 76.1 | 69.3 | |||
Sound power | ||||||||||||||
(m3/h) | p (Pa) | Filter | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 | Total Lw (dB) | Total weighed (dB(A)) | ||
90
|
50 | ISO Coarse 60% | 61.0 | 53.5 | 43.3 | 34.8 | 18.7 | 14.3 | 15.9 | 20.9 | 61.7 | 41.2 | ||
100 | ISO Coarse 60% | 59.5 | 47.1 | 44.9 | 36.7 | 21.6 | 17.7 | 16.0 | 20.9 | 59.9 | 40.1 | |||
150
|
50 | ISO Coarse 60% | 58.0 | 52.9 | 50.0 | 42.3 | 26.1 | 23.2 | 16.9 | 20.9 | 59.7 | 44.6 | ||
100 | ISO Coarse 60% | 60.7 | 60.8 | 54.3 | 44.8 | 28.1 | 25.1 | 17.2 | 20.8 | 64.3 | 49.3 | |||
210
|
50 | ISO Coarse 60% | 59.4 | 53.4 | 57.5 | 48.8 | 32.6 | 30.8 | 22.0 | 20.8 | 62.4 | 51.0 | ||
100 | ISO Coarse 60% | 63.7 | 57.1 | 58.5 | 49.5 | 33.3 | 31.5 | 21.7 | 21.0 | 65.6 | 52.1 | |||
300
|
50 | ISO Coarse 60% | 61.0 | 57.6 | 65.2 | 56.7 | 40.5 | 38.5 | 29.9 | 21.7 | 67.5 | 58.6 | ||
100 | ISO Coarse 60% | 63.6 | 58.1 | 64.5 | 56.9 | 41.1 | 39.2 | 31.9 | 22.1 | 68.0 | 58.3 | |||
Sound power | ||||||||||||||
(m3/h) | p (Pa) | Filter | 63 | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 | Total Lw (dB) | Total weighed (dB(A)) | ||
90
|
50 | ISO Coarse 60% | 41.5 | 34.8 | 35.8 | 27.2 | 20.0 | 14.6 | 15.9 | 20.8 | 30.0 | |||
100 | ISO Coarse 60% | 41.6 | 40.4 | 37.3 | 30.2 | 23.9 | 16.8 | 15.9 | 20.6 | 33.0 | ||||
150
|
50 | ISO Coarse 60% | 39.6 | 47.5 | 41.6 | 33.8 | 25.2 | 20.8 | 16.5 | 20.8 | 38.0 | |||
100 | ISO Coarse 60% | 42.1 | 43.6 | 43.8 | 35.9 | 26.7 | 22.2 | 16.9 | 20.6 | 38.0 | ||||
210
|
50 | ISO Coarse 60% | 40.6 | 41.3 | 52.6 | 42.4 | 31.9 | 26.5 | 19.0 | 21.9 | 44.0 | |||
100 | ISO Coarse 60% | 41.7 | 42.3 | 54.7 | 43.8 | 33.2 | 27.8 | 20.3 | 21.2 | 46.0 | ||||
300
|
50 | ISO Coarse 60% | 42.7 | 48.8 | 56.0 | 48.0 | 39.1 | 37.0 | 30.6 | 26.5 | 50.0 | |||
100 | ISO Coarse 60% | 44.9 | 49.5 | 57.6 | 48.9 | 40.3 | 38.0 | 31.9 | 28.4 | 52.0 |
More About The Brink Climate System
The Brink Renovent Sky 300 is a mechanical ventilation with heat recovery unit with a high efficiency, low-energy fans and a maximum ventilation capacity of 150m3/h. At CVC Direct we are happy to plan, deliver and install your complete ventilation project or heating recovery system. If you’d like more information about any of our systems for home ventilation our highly qualified team are here to help.