Brink Renovent Sky 150

Heat Recovery Ventilation

The Brink Renovent Sky 150 is a mechanical ventilation with heat recovery unit with high efficiency, low-energy fans and a maximum ventilation capacity of 150m3/h. The Brink Renovent Sky 150 comes ready to plug in with a 230V mains plug and with the aid of the mounting brackets the unit can be mounted either on the wall or on the ceiling. The Sky 150 comes with a digital controller supplied as standard.

Features of the Brink Renovent Sky 150:

  • ​Adjustable airflow rates via the control unit
  • Filter change indication
  • Frost protection
  • Summer bypass
  • Low energy consumption
  • High efficiency

The Brink Renovent Sky 150 is a ventilation unit with heat recovery with a maximum ventilation capacity of 150 m3/h and low-energy fans.

Features of the Brink Renovent Sky 150: 

  • Steplessly adjustable air flow rates through a control unit (supplied with appliance).
  • Filter indication on the control unit / multiple switch.
  • A completely new intelligent frost protection system which ensures that also at low outdoor temperatures the appliance’s performance remains optimal and that, if necessary, it activates the standard preheater.
  • Low sound level
  • Comes as standard with automatic bypass valve
  • Constant flow control
  • Low energy consumption
  • High efficiency

The Brink Renovent Sky 150 is available in two types: 

  • “Renovent Sky 150”
  • “Renovent Sky 150 Plus”

Compared to the Renovent Sky 150, the Renovent Sky 150 Plus has a more extensive control board which increases the connection options.

SKY 150
Supply Voltage 230V/50Hz
Dimensions (wxdxh) (mm) 1000 x 660 x 198
Duct diameter (mm) 125
External diameter condensate discharge (mm) 3/4
Weight (kg) 37
Filter class G4
Fan Setting (factory setting) 0 1 2 3 max
Factory Setting (m3/hr) 30 75 100 125 150
Permissible resistance of duct system (Pa) 2-6 13-38 22-66 35-105 50-150
Rated power (excl. preheater) (W) 11-12 19-27 27-37 38-52 53-72
Rated current (excl. preheater) (A) 0.14-0.15 0.20-0.28 0.27-0.35 0.36-0.47 0.49-0.64
Max. rated current (incl. preheater switched on) (A) 6
Cos 0.340 0.420 0.44-0.47 0.46-0.48 0.47-0.49
Sound power
(m3/h) p (Pa) Filter 63 125 250 500 1000 2000 4000 8000 Total Lw (dB) Total weighed (dB(A))
45
10 ISO Coarse 60% 68.1 54.9 46.5 42.3 9.6 29.4 20.9 19.3 68.3 45.8
50 ISO Coarse 60% 76.4 63.6 56.0 48.5 47.9 41.1 34.0 24.9 76.6 55.1
100 ISO Coarse 60% 83.6 71.2 62.5 54.8 56.8 51.5 45.8 39.1 83.9 62.9
75
25 ISO Coarse 60% 74.0 62.6 55.6 48.6 49.7 41.0 33.4 24.0 74.4 54.7
50 ISO Coarse 60% 77.0 65.8 58.0 51.2 52.9 43.6 37.2 27.8 77.4 57.7
100 ISO Coarse 60% 81.2 71.2 63.1 55.6 56.6 48.1 42.8 35.0 81.7 62.2
105
50 ISO Coarse 60% 79.4 67.9 61.9 54.7 56.8 47.8 42.4 34.2 79.8 61.1
100 ISO Coarse 60% 82.1 72.0 64.6 57.6 59.3 51.7 46.8 39.9 82.6 64.0
150
50 ISO Coarse 60% 82.2 73.7 69.0 60.7 60.7 54.0 49.5 43.2 83.0 66.2
100 ISO Coarse 60% 84.8 75.3 70.7 63.6 61.9 57.3 52.5 46.9 85.4 68.2
Sound power
(m3/h) p (Pa) Filter 63 125 250 500 1000 2000 4000 8000 Total Lw (dB) Total weighed (dB(A))
45
10 ISO Coarse 60% 62.2 48.1 36.4 27.7 20.1 12.3 15.2 19.1 62.4 38.2
50 ISO Coarse 60% 62.4 56.6 48.3 36.5 31.9 17.6 15.7 19.1 63.5 44.5
100 ISO Coarse 60% 64.8 62.4 54.3 42.0 37.7 24.9 18.6 19.2 67.0 50.0
75
25 ISO Coarse 60% 63.4 56.9 45.4 35.0 29.7 16.9 15.5 19.1 64.3 43.9
50 ISO Coarse 60% 61.1 58.4 49.1 37.5 31.8 18.6 16.0 19.1 63.1 45.5
100 ISO Coarse 60% 63.4 61.3 56.3 43.5 36.1 22.7 17.6 20.5 66.0 50.5
105
50 ISO Coarse 60% 61.1 60.1 52.1 41.1 35.8 22.7 17.6 19.2 63.9 47.8
100 ISO Coarse 60% 63.6 62.6 56.6 44.4 38.1 26.0 19.5 19.3 66.6 51.2
150
50 ISO Coarse 60% 64.6 64.6 59.5 48.0 40.2 29.1 21.7 19.7 68.3 53.8
100 ISO Coarse 60% 63.0 66.0 60.5 49.3 41.2 31.3 23.4 20.1 68.5 55.0
Sound power
(m3/h) p (Pa) Filter 63 125 250 500 1000 2000 4000 8000 Total Lw (dB) Total weighed (dB(A))
45
10 ISO Coarse 60% 43.6 36.2 27.3 24.3 19.9 12.1 15.0 19.0 27.6
50 ISO Coarse 60% 44.3 45.8 36.4 28.3 27.8 16.9 15.3 19.0 34.3
100 ISO Coarse 60% 47.9 53.2 42.0 34.4 33.5 23.1 17.1 19.1 40.5
75
25 ISO Coarse 60% 45.2 43.8 36.0 27.8 27.3 16.1 15.2 19.0 33.4
50 ISO Coarse 60% 47.2 46.8 39.0 30.2 29.6 17.7 15.5 19.1 36.0
100 ISO Coarse 60% 48.5 51.0 44.4 36.0 32.6 22.0 16.8 19.1 40.4
105
50 ISO Coarse 60% 46.6 48.7 43.0 33.7 32.9 21.3 16.5 19.1 39.0
100 ISO Coarse 60% 48.7 52.1 45.4 37.0 34.6 24.5 18.0 19.1 41.6
150
50 ISO Coarse 60% 49.5 54.3 49.7 40.7 36.6 27.8 19.8 19.3 44.8
100 ISO Coarse 60% 52.4 56.2 50.2 41.5 37.5 29.8 21.1 19.4 45.8

More About The Brink Climate System

The Brink Renovent Sky 150 is a mechanical ventilation with heat recovery unit with high efficiency, low-energy fans and a maximum ventilation capacity of 150m3/h. At CVC Direct we are happy to plan, deliver and install your complete ventilation project or heating recovery system. If you’d like more information about any of our systems for home ventilation our highly qualified team are here to help.